Air flow test system

Controlling the flow up to 70m3/h with a pressure from  10 to 500Pa, measured on the device to be tested (DUT).


Also can this be a under pressure instead an over pressure. Thereby this system is suitable to test heat exchange units. One circuit 

can be pressure control to a level, and the other circuit tested on leakages.

For testing a very precise defined leak (orifice) for the semiconductor industry is made. Under several pressures

the assembly is tested with an accurate flow measurement, connected to a Codesys based PLC system.

Contact

info@lttechnology.nl

Wim Terpstra: +31 (0) 6 29 56 45 48
Bert Lenderink: +31 (0) 6 20 60 20 59

Printer 8
7741 MD Coevorden